Air/Vapour Barrier:
Code Green
Advanced Coatings Inc.
Head Office:
15288 Hwy 12,
P.O. Box 670
Midland, Ontario L4R 4P4
Toll Free: 1-800-787-8059
Tel: (705)534-4760
Fax: (705)534-4125
Branch Office:
22 Oxenden Cres.
Etobicoke, Ontario
M9C 4H4
Toll Free: 1-800-730-0814
Tel: (416)410-0814
Fax: (416)695-2480
|
|
|
Code Green specifications can be downloaded here:
Code Green
Specifications
|
You will need Adobe Acrobat to open this
file
|
|
|
Basic Use: Primarily intended as a non-accessible
air/vapour barrier for all types of cavity wall construction. (e.g.
over exterior face of inner wythe of masonry cavity wall)
New construction or retrofit.
For commercial, industrial and institutional applications.
Composition and Materials:
Code Green is a 100% rubber copolymer liquid applied air/vapour
barrier membrane (hydrocarbon polymers in hydrocarbon solvents)
that is spray applied to the substrate by manufacturer approved
applicators.
Transition joints in the substrate to receive Code Green are first
sealed with Rub-R-Wall SA, a self-adhering, cold applied composite
sheet mebrane (transition strip). These strips, approximately 150
mm (6") wide, are located at beams, columns, changes in substrate
material, and similiar joints or connections to provide continuity
of the air/vapour barrier assembly.
Code Green meets all of the principal requirements and design criteria
for a properly constructed air barrier for the building envelope,
namely:
- resistance to air flow;
- structural soundness, capable of resisting wind and other
loads, over its expected life span;
- continuity throughout the building envelope;
- be permanent if concealed.
Thickness: 1 mm (40 mils)
Application Rate (over standard concrete block): 2.6
to 3 m²/4.5 L (28 to 32 sq ft/gal)
Colour: Bright Green
Limitations: Not designed to perform as a permanently
exposed membrane.
Applicable Standards: Meets and exceeds the
National Research Council (NRC) Type III Air Leakage requirements.
Meets the requirements of ASTM E-96 Type I water vapour permeance.
See the Physical Properties Chart below.
Environmental Considerations: Code Green membrane
is non-toxic, non-carcinogenic and will not contaminate ground water.
Preparatory Work:
Refer to the Examination section of the specification for substrate
requirements by others (new construction).
Under the work of the air/vapour barrier section of work, the following
preparatory requirements include:
1. Removing loose or foreign matter which might impair adhesion
of materials.
2. Filling any voids with a proprietary mastic substrate filler
(Code Green Mastic).
3. Cleaning and priming substrate joint/connection surfaces and
applying Rub-R-Wall SA "transition strip."
Methods: Code Green is applied using manufacturer
approved applicators who undergo extensive training and are monitored
for quality performance.
Applied over outer surface of inner whythe of masonry or other substrate,
Code Green is sprayed on to surfaces using alternating horizontal
and vertical passes to ensure complete coverage of substrate and
Rub-R-Wall SA material. Masonry anchors or other penetrations are
sealed air tight.
Transition joints are sealed using Rub-R-Wall SA over firm bearing
at beams, columns, changes in substrate material and similiar joints
or connections including at window frame perimeter and door frames.
Generally strips are applied so that a minimum of 75 mm (3") coverage
is achieved over both substrates, and with 25 mm (1") of full contact
over window or door frames.
Code Green is applied within the recommended application temperature
range. It may be applied successfully at temperatures as low as
-15°C (5°F).
Airless spray equipment having a minimum pressure of 20 684 kPa
(3000 psi) is used to apply Code Green. The coverage rate of the
completed membrane application is 2.6 to 3 m²/4.5 L (28 to 32
sq ft/gal) which provides a seamless, monolithic surface with a
final thickness of 1 mm (40 mils). Typically, one crew can apply
approximately 372 m² (4000 sq ft) of area per day. Drying time
of Code Green is approximately one hour, given average conditions
an standard thickness.
A spray or board type cavity wall insulation is then adhered to
the Code Green air/vapour barrier membrane after an initial set
time of approximately 1 to 2 hours, and while the membrane is still
tacky, to prevent convection currents occuring behind the insulation.
Once applied, the insulation is firmly and permanently adhered into
place and cannot be removed. Wedges or clips, normally used to secure
the insulation may be reduced or eliminated.
Building Codes: Code Green meets the intent of Part
5 (Section 5.3 Control of Air Leakage, Subsection 5.3.1 Air Barriers)
of the National Building Code (NBC).
(Imperial
Measure. Metric chart available upon request)
| Property |
Test Method |
Test Results |
| Air Leakage Rate |
ASTM E283 |
0.00220 L/s.m² (considerably
lower than the 0.05 L/s.m² value for a type III air barrier
as proposed by National Research Council) |
| Elongation (%) |
ASTM D412 (die C) |
1800% |
| Low-Temperature Flexibility |
Bend around 0.5 inch mandrel |
Flexible to -20°F (-29°C)
|
| Abrasion Resistance |
700 PSI on .06" x .06" point moving
1" per sec. |
Less than 0.10% membrane loss |
| Asphalt Content |
Non Applicable |
0.0% |
| 180° Peel Adhesion |
Metal Plate |
18 lbs/inch |
| Crack Bridging |
ASTM 836 |
Exceeds ten cycles to 1/8 inch at
-15°F (-26°C) |
| Water Vapour Permeance |
ASTM E96 (water method) |
12.09 ng/Pa.s.m² for 40 mil (1
mm) dry coating grams/ft²/hr in Hg |
| Liquid Water Absorption |
ASTM D95 |
Less than 0.5% (weight) |
| Resistance to Bacteria |
ASTM D4299-83 (modified) |
No attack |
| Resistance to Gust Wind Load |
ASTM E330 |
Resists a suction pressure of 3000
Pa (62.8 lbs/ft²) maintained for 10 seconds with no delamination
and no increase in air leakage rate when tested at 75 Pa (1.6
lbs/ft²) |
| Resistance to Sustained Wind Load
|
ASTM E283 |
Resists a suction pressure of 1000
Pa (20.9 lbs/ft²) maintained for 10 seconds with no delamination
and no increase in air leakage rate when tested at 75 Pa (1.6
lbs/ft²) |
| Resistance to Chemical Attack |
Visual |
Unaffected by chemicals in concentrations
typically found in soils |
| Solvent Resistance |
Visual |
Exceeds performance of modified asphalts
|
| Life Expectancy |
ASTM D412 and ASTM D2240 |
Exceeds 100 years |
| Density |
|
0.9 kg/L |
*Tests conducted by the Ortech Corporation of Mississauga, Ontario
and the Akron Rubber Development Labratory Inc., Akron, Ohio. Copy
of test reports available upon request.
Availability: Code Green is available across Canada
and throughout the U.S., usually shipped from stock. Contact Advanced
Coatings Inc. for a list of dealers/applicators.
Cost: A current price list is available from the dealers/applicators
along with standard conditions of sale.
The information herein is the best available relating to Code Green.
The recommendations contained herein are based on tests believed
to be reliable. We warrant our products to be of merchantable quality
and suitable for the purpose for which they are intended. We do
not make any other warranties, expressed or implied, statutory or
otherwise.
Code Green membrane does not require any maintenance. Damaged areas
are easily repaired by spraying over affected areas. Cold joints
or recoating is not a problem; newly applied material easily blends
with existing Code Green material to provide a monolithic membrane.
For technical support call Advanced Coatings Inc. toll free.
Head Office: 1-800-787-8059
Branch Office: 1-800-730-0814
Specification assistance.
Site advice and recommendations.
Construction Specifications Canada (CSC) Tek-Aid 07195 Air Barriers
(Digest, and Master Specification).
National Master Specification (NMS) Section 07196 Air Barriers (Descriptive/Proprietary).
"An Air Barrier for the Building Envelope, National Research Council
Canada, Proceedings Building Science Insight '86."
|