Basic Use: A waterproofing membrane for vertical
and horizontal building elements below grade such as walls, slabs
and decks. Code Blue prevents the passage of water under hydrostatic,
dynamic or static pressure.
Example uses include:
- foundation walls
- parking garage decks and ramps
- plazas, podiums and pedestrian concourses
- elevator shafts
- tunnels and bridge decks
New construction or retrofit.
For commercial, industrial and institutional applications.
Composition and Materials:
Code Blue is a 100% rubber copolymer liquid applied waterproofing
membrane (hydrocarbon polymers in hydrocarbon solvents) that is
spray applied to the substrate by manufacturer approved applicators.
The more complicated the surface to be waterproofed, the more reason
to use a liquid applied membrane. Code Blue membrane can conform
to all irregular shapes whereas a sheeting product must be precisely
cut and fitted, pieced and seamed whether by hot air welding or
adhesive methods. As well as ensuring a thorough waterproofing job,
the ease and simplicity of application will also reduce labour costs
when compared with sheeting products or built up membrane systems.
The ability of Code Blue to conform to all irregularities whether
intended or not makes it an ideal choice for re-waterproofing where
there is little control over initial substrate quality.
There are no seasonal restrictions because Code Blue can be applied
at low temperatures providing substrates are dry and frost-free.
Once the membrane is applied, it is impermeable to water. The excellent
and tenacious bond of the membrane to substrates prevents the lateral
movement of water between the membrane and substrate.
The system used for waterproofing:
Is a single layer membrane application (reinforced at joints or
cracks) consisting of spraying a 1 mm (40 mils) thickness of membrane
over a properly prepared substrate.
Limitations:
In all cases the waterproofing must be protected from ultraviolet
light rays and mechanical damage and should not be left permanently
exposed. It can be protected by means of a protection board or rigid
insulation, plus landscaping, pavers, concrete or asphalt paving.
Thickness:
1 mm (40 mils) for single layer applications.
Application Rate:
Over poured walls, floors, or parged block: 2.3 m²
to 3.3 m²/4.5 L (25 to 35 sq ft/gal).
Over standard concrete block: 1.9 m² to 2.5 m²/4.5 L (20
to 27 sq ft/gal).
Colour:
Blue
Applicable Standards: Meets the requirements
of ASTM E-96 Type 1 water vapour permeance. Refer to the Physical
Properties chart below for a complete list of ASTM Standards governing
Code Blue properties.
Environmental Considerations: The Code Blue membrane
is non-toxic, non-carcinogenic and will not contaminate ground water.
Preparatory Work:
The successful performance of Code Blue relies on a 100% bond to
the substrate. To achieve complete adhesion, certain substrate requirements
are necessary. Surfaces should be relatively smooth, clean, solid,
free of scaling, fins, honeycombed areas, loose material, frost,
dampness, dust, dirt, oil, grease, curing compounds and other foreign
matter detrimental to adhesion of membrane.
Concrete surfaces should have a wood float finish or smoother. Refer
to the examination section of the specification for substrate requirements
by others (new construction).
Under the work of the waterproofing section of work, the following
preparatory requirements include:
1. Removing loose or foreign matter which might impair adhesion
of materials.
2. Filling any minor imperfections in the substrates such as form
tie holes and cracks with a proprietary mastic substrate filler
(Code Blue Mastic).
3. Priming any damp substrate areas if necessary with Code Blue
"Wet Prime" low viscosity primer within the moisture tolerance levels
as determined by Advanced Coatings Inc.
Methods: Code Blue is applied using manufacturer approved
applicators who undergo extensive training and are monitored for
quality performance.
Code Blue is sprayed on to surfaces using alternating horizontal
and vertical passes to ensure complete coverage of substrate. Penetrations
are sealed water tight.
Code Blue is applied within the recommended application temperature
range. It may be applied successfully at temperatures as low as
-15°C (5°F).
Airless spray equipment having a minimum pressure of 20 684 kPa
(3000 psi) is used to apply Code Blue.
The coverage rate of the completed membrane application provides
a seamless, monolithic surface with a final thickness of 1 mm (40
mils).
Typically, one man can apply approximately 372 m² (4000 sq ft)
of area per day. Drying time of Code Blue is approximately one hour,
given average conditions and standard thickness, and may be influenced
by relative humidity, temperature and air flow.
Protection board or insulation may be applied to membrane surfaces
after an initial set time of approximately 20 minutes while the
membrane is still tacky, to prevent damage from coverings such as
backfill, overburden, concrete, asphalt pavement or pavers. Once
applied, this protection board (or insulation) is firmly and permanently
adhered into place and cannot be removed. Where insulation acts
as the protective cover on vertical surfaces, wedges or clips normally
used to secure the insulation, are eliminated.
Precautions: Protection board or insulation will adhere
tenaciously to the Code Blue membrane so care must be taken to ensure
proper initial placement.
Do not backfill before the recommended 24 hours after membrane application.
Ensure that backfill material is free of debris, organic material,
boulders, rocks, concrete block debris or any other deleterious
material not considered suitable fill.
Ensure that footing drains are installed in accordance with building
code requirements.
Building Codes: Code Blue meets the intent of Part
5 (Section 5.5.2 - Dampproofing and Waterproofing) and Part 9 (Section
9.13 - Waterproofing and Dampproofing and 9.13 - Slabs-on Ground)
of the National Building Code (NBC).
(Imperial
Measure. Metric chart available upon request)
| Property |
Test Method |
Test Results |
| Water Vapour Permeance |
ASTM E96 (water method) |
0.21 perms for 40 mil dry coating
grams/ft²/hr in Hg. |
| Elongation (%) |
ASTM D412 (die C) |
1800% |
| Low-Temperature Flexibility |
Bend around 0.5 inch mandrel |
Flexible to -20°F (-29°C)
|
| Abrasion Resistance |
700 PSI on .06" x .06" point moving
1" per sec. |
Less than 0.10% membrane loss |
| Asphalt Content |
Non Applicable |
0.0% |
| 180° |
Metal Plate |
18 lbs/inch |
| Crack Bridging |
ASTM C836 |
Exceeds ten cycles to 1/8 inch at
-15°F (-26°C) |
| Liquid Water Absorption |
ASTM D95 |
Less than 0.5% (weight) |
| Resistance to Bacteria |
ASTM D4299-83 (modified) |
No attack |
| Resistance to Degradation in Soil
|
ASTM E154 (soil preperation) |
Excellent |
| Resistance to Algae |
ASTM G29-75 (modified) |
No attack |
| Resistance to Fungus |
ASTM D2020 (modified) |
No attack |
| Resistance to Chemical Attack |
Visual |
Unaffected by chemicals in concentrations
typically found in soils |
| Solvent Resistance |
Visual |
Exceeds performance of modified asphalts
|
| Life Expectancy |
ASTM D412 and ASTM D2240 |
Exceeds 100 years |
| Density |
|
6.8 - 7.8 lbs/gal 0.9 kg/L (approx.)
|
*Tests conducted by the Ortech Corporation of Mississauga, Ontario
and the Akron Rubber Development Labratory Inc., Akron, Ohio. Copy
of test data available upon request.
Availability: Code Blue is available across Canada
and throughout the U.S., usually shipped from stock. Contact Advanced
Coatings Inc. for a list of applicators.
Cost: A current price list is available from the applicators
along with the standard conditions of sale.
The information herein is the best available relating to Code Blue.
The recommendations contained herein are based on tests believed
to be reliable. We warrant our products to be of merchantable quality
and suitable for the purpose for which they are intended. We do
not make any other warranties, expressed or implied, statutory or
otherwise.
Code Blue membrane does not require any maintenance. Damaged areas
are easily repaired by spraying over affected areas. Cold joints
or re-coating is not a problem; newly applied material easily blends
with existing Code Blue material to provide a monolithic membrane.
For technical support call Advanced Coatings Inc. toll free.
Head Office: 1-800-787-8059
Branch Office: 1-800-730-0814
Specification assistance.
Site advice and recommendations.
Accompanying Master Specification (Microsoft Word) suitable for
use by specifying authorities.
Advanced Coatings Inc. Code Blue Waterproofing Manu-Data literature.
|
ABOUT US | WHAT'S
NEW | CONTACT US |
WATERPROOFING | AIR/VAPOUR
BARRIERS | ROOFING
SPRAY INSULATION | SEALANTS
| DAMPPROOFING | DRAINAGE
MEMBRANES | ATLAS BLOCK
| HOME |
|