1. Product Name
Fluid Applied Waterproofing:
Rub-R-Wall

2. Manufacturer
Advanced Coatings Inc.

Head Office:
15288 Hwy 12, P.O. Box 670
Midland, Ontario L4R 4P4
Toll Free: 1-800-787-8059
Tel: (705)534-4760
Fax: (705)534-4125

Branch Office:
22 Oxenden Cres.
Etobicoke, Ontario M9C 4H4
Toll Free: 1-800-730-0814
Tel: (416)410-0814
Fax: (416)695-2480

Specifications
Rub-R-Wall specifications can be downloaded here:
Rub-R-Wall Specifications

You will need Adobe Acrobat to open this file

3. Product Description
Basic Use: A waterproofing membrane for vertical and horizontal building elements below grade such as walls, slabs and decks. Rub-R-Wall prevents the passage of water under hydrostatic, dynamic or static pressure.

Example uses include:
  • foundation walls
  • parking garage decks and ramps
  • plazas, podiums and pedestrian concourses
  • elevator shafts
  • tunnels and bridge decks
New construction or retrofit.

For commercial, industrial and institutional applications.

Composition and Materials:
Rub-R-Wall is a 100% rubber copolymer liquid applied waterproofing membrane (hydrocarbon polymers in hydrocarbon solvents) that is spray applied to the substrate by manufacturer approved applicators.

The more complicated the surface to be waterproofed, the more reason to use a liquid applied membrane. Rub-R-Wall membrane can conform to all irregular shapes whereas a sheeting product must be precisely cut and fitted, pieced and seamed whether by hot air welding or adhesive methods. As well as ensuring a thorough waterproofing job, the ease and simplicity of application will also reduce labour costs when compared with sheeting products or built up membrane systems.

The ability of Rub-R-Wall to conform to all irregularities whether intended or not makes it an ideal choice for re-waterproofing where there is little control over initial substrate quality.

There are no seasonal restrictions because Rub-R-Wall can be applied at low temperatures providing substrates are dry and frost-free. Once the membrane is applied it is impermeable to water. The excellent and tenacious bond of the membrane to substrates prevents the lateral movement of water between the membrane and substrate.

The system used for waterproofing:

Is a single layer membrane application (reinforced at joints or cracks) consisting of spraying a 1 mm (40 mils) thickness of membrane over a properly prepared substrate.

Limitations:
In all cases the waterproofing must be protected from ultraviolet light rays and mechanical damage and should not be left permanently exposed. It can be protected by means of protection board or rigid insulation, plus landscaping, pavers, concrete or asphalt paving.

Thickness:
1 mm (40 mils) for single layer applications.

Application Rate:
Over poured walls, floors, or parged block: 2.3 m² to 3.3 m²/4.5 L (25 to 35 sq ft/gal).
Over standard concrete block: 1.9 m² to 2.5 m²/4.5 L (20 to 27 sq ft/gal).

Colour:
Green

4. Technical Data
Applicable Standards: Meets the requirements of ASTM E-96 Type 1 water vapour permeance. Refer to the Physical Properties chart below for a complete list of ASTM Standards governing Rub-R-Wall properties.

Environmental Considerations: The Rub-R-Wall membrane is non-toxic, non-carcinogenic and will not contaminate ground water.

5. Installation
Preparatory Work:
The successful performance of Rub-R-Wall relies on a 100% bond to the substrate. To achieve complete adhesion, certain substrate requirements are necessary. Surfaces should be relatively smooth, clean, solid, free of scaling, fins, honeycombed areas, loose material, frost, dampness, dust, dirt, oil, grease, curing compounds and other foreign matter detrimental to adhesion of membrane.

Concrete surfaces should have a wood float finish or smoother. Refer to the examination section of the specification for substrate requirements by others (new construction).

Under the work of the waterproofing section of work, the following preparatory requirements include:

1. Removing loose or foreign matter which might impair adhesion of materials.

2. Filling any minor imperfections in the substrates such as form tie holes and cracks with a proprietary mastic substrate filler (Rub-R-Wall Mastic).

3. Priming any damp substrate areas if necessary with Rub-R-Wall "Wet Prime" low viscosity primer within the moisture tolerance levels as determined by Advanced Coatings Inc.

Methods: Rub-R-Wall is applied using manufacturer approved applicators who undergo extensive training and are monitored for quality performance.

Rub-R-Wall is sprayed on to surfaces using alternating horizontal and vertical passes to ensure complete coverage of substrate. Penetrations are sealed water tight.

Rub-R-Wall is applied within the recommended application temperature range. It may be applied successfully at temperatures as low as -15°C (5°F).

Airless spray equipment having a minimum pressure of 20 684 kPa (3000 psi) is used to apply Rub-R-Wall.

The coverage rate of the completed membrane application provides a seamless, monolithic surface with a final thickness of 1 mm (40 mils).

Typically, one man can apply approximately 372 m² (4000 sq ft) of area per day. Drying time of Rub-R-Wall is approximately one hour, given average conditions and standard thickness, and may be influenced by relative humidity, temperature and air flow.

Protection board or insulation may be applied to membrane surfaces after an initial set time of approximately 20 minutes while the membrane is still tacky, to prevent damage from coverings such as backfill, overburden, concrete, asphalt pavement or pavers. Once applied, this protection board (or insulation) is firmly and permanently adhered into place and cannot be removed. Where insulation acts as the protective cover on vertical surfaces, wedges or clips normally used to secure the insulation, are eliminated.

Precautions: Protection board or insulation will adhere tenaciously to the Rub-R-Wall membrane so care must be taken to ensure proper initial placement.

Do not backfill before the recommended 24 hours after membrane application. Ensure that backfill material is free of debris, organic material, boulders, rocks, concrete block debris or any other deleterious material not considered suitable fill.

Ensure that footing drains are installed in accordance with building code requirements.

Building Codes: Rub-R-Wall meets the intent of Part 5 (Section 5.5.2 - Dampproofing and Waterproofing) and Part 9 (Section 9.13 - Waterproofing and Dampproofing and 9.13 - Slabs-on Ground) of the National Building Code (NBC).

Typical Physical Properties* (Imperial Measure. Metric chart available upon request)
Property Test Method Test Results
Water Vapour Permeance ASTM E96 (water method) 0.21 perms for 40 mil dry coating grams/ft²/hr in Hg.
Elongation (%) ASTM D412 (die C) 1800%
Low-Temperature Flexibility Bend around 0.5 inch mandrel Flexible to -20°F (-29°C)
Abrasion Resistance 700 PSI on .06" x .06" point moving 1" per sec. Less than 0.10% membrane loss
Asphalt Content Non Applicable 0.0%
180° Metal Plate 18 lbs/inch
Crack Bridging ASTM C836 Exceeds ten cycles to 1/8 inch at -15°F (-26°C)
Liquid Water Absorption ASTM D95 Less than 0.5% (weight)
Resistance to Bacteria ASTM D4299-83 (modified) No attack
Resistance to Degradation in Soil ASTM E154 (soil preperation) Excellent
Resistance to Algae ASTM G29-75 (modified) No attack
Resistance to Fungus ASTM D2020 (modified) No attack
Resistance to Chemical Attack Visual Unaffected by chemicals in concentrations typically found in soils
Solvent Resistance Visual Exceeds performance of modified asphalts
Life Expectancy ASTM D412 and ASTM D2240 Exceeds 100 years
Density
6.8 - 7.8 lbs/gal 0.9 kg/L (approx.)

*Tests conducted by the Ortech Corporation of Mississauga, Ontario and the Akron Rubber Development Labratory Inc., Akron, Ohio. Copy of test data available upon request.

6. Availability and Cost
Availability: Rub-R-Wall is available across Canada and throughout the U.S., usually shipped from stock. Contact Advanced Coatings Inc. for a list of applicators.

Cost: A current price list is available from the applicators along with the standard conditions of sale.

7. Warranty
The information herein is the best available relating to Rub-R-Wall. The recommendations contained herein are based on tests believed to be reliable. We warrant our products to be of merchantable quality and suitable for the purpose for which they are intended. We do not make any other warranties, expressed or implied, statutory or otherwise.

8. Maintenance
Rub-R-Wall membrane does not require any maintenance. Damaged areas are easily repaired by spraying over affected areas. Cold joints or re-coating is not a problem; newly applied material easily blends with existing Rub-R-Wall material to provide a monolithic membrane.

9. Technical Services
For technical support call Advanced Coatings Inc. toll free.

Head Office: 1-800-787-8059
Branch Office: 1-800-730-0814

Specification assistance.
Site advice and recommendations.

10. Related References
Accompanying Master Specification (Microsoft Word) suitable for use by specifying authorities.

Advanced Coatings Inc. Rub-R-Wall Waterproofing Manu-Data literature.